TY - JOUR
T1 - Analysis of the socket bone wall dimensions in the upper maxilla in relation to immediate implant placement
AU - Huynh-Ba, Guy
AU - Pjetursson, Bjarni E.
AU - Sanz, Mariano
AU - Cecchinato, Denis
AU - Ferrus, Jorge
AU - Lindhe, Jan
AU - Lang, Niklaus P.
PY - 2010/1
Y1 - 2010/1
N2 - Background: Animal and human researches have shown that immediate implant placement into extraction sockets failed to prevent socket dimensional changes following tooth extraction. It has been suggested that a minimal width of 1-2 mm of buccal bone is necessary to maintain a stable vertical dimension of the alveolar crest. Aim: To determine the dimensions of the bony wall at extraction sites in the esthetic zone (anterior teeth and premolars in the maxilla) and relate it to immediate implant placement. Methods: As part of an ongoing prospective randomized-controlled multicenter clinical study on immediate implant placement, the width of the buccal and palatal bony walls was recorded at 93 extraction sites. Results: The mean width of the buccal and palatal bony walls was 1 and 1.2 mm, respectively (P<0.05). For the anterior sites (canine to canine), the mean width of the buccal bony wall was 0.8 mm. For the posterior (premolar) sites, it was 1.1 mm (P<0.05). In the anterior sites, 87% of the buccal bony walls had a width ≤1 mm and 3% of the walls were 2 mm wide. In the posterior sites, the corresponding values were 59% and 9%, respectively. Conclusions: If the criterion of a minimal buccal bone width of 2 mm to maintain a stable buccal bony wall is valid, only a limited number of sites in the anterior maxilla display such a clinical situation. The data suggested that in the majority of extraction sites in the anterior maxilla, thin (≤1 mm) buccal walls were present. This, in turn, means that in most clinical situations encountered, augmentation procedures are needed to achieve adequate bony contours around the implant.
AB - Background: Animal and human researches have shown that immediate implant placement into extraction sockets failed to prevent socket dimensional changes following tooth extraction. It has been suggested that a minimal width of 1-2 mm of buccal bone is necessary to maintain a stable vertical dimension of the alveolar crest. Aim: To determine the dimensions of the bony wall at extraction sites in the esthetic zone (anterior teeth and premolars in the maxilla) and relate it to immediate implant placement. Methods: As part of an ongoing prospective randomized-controlled multicenter clinical study on immediate implant placement, the width of the buccal and palatal bony walls was recorded at 93 extraction sites. Results: The mean width of the buccal and palatal bony walls was 1 and 1.2 mm, respectively (P<0.05). For the anterior sites (canine to canine), the mean width of the buccal bony wall was 0.8 mm. For the posterior (premolar) sites, it was 1.1 mm (P<0.05). In the anterior sites, 87% of the buccal bony walls had a width ≤1 mm and 3% of the walls were 2 mm wide. In the posterior sites, the corresponding values were 59% and 9%, respectively. Conclusions: If the criterion of a minimal buccal bone width of 2 mm to maintain a stable buccal bony wall is valid, only a limited number of sites in the anterior maxilla display such a clinical situation. The data suggested that in the majority of extraction sites in the anterior maxilla, thin (≤1 mm) buccal walls were present. This, in turn, means that in most clinical situations encountered, augmentation procedures are needed to achieve adequate bony contours around the implant.
KW - Bone
KW - Defect
KW - Dental implant
KW - Extraction socket
KW - Resorption
KW - Width
UR - http://www.scopus.com/inward/record.url?scp=72949085306&partnerID=8YFLogxK
U2 - 10.1111/j.1600-0501.2009.01870.x
DO - 10.1111/j.1600-0501.2009.01870.x
M3 - Article
C2 - 20070745
AN - SCOPUS:72949085306
SN - 0905-7161
VL - 21
SP - 37
EP - 42
JO - Clinical Oral Implants Research
JF - Clinical Oral Implants Research
IS - 1
ER -