Abstract
In this memo a method for calculating the discharge through each turbine and the total water discharge through a power station will be presented. Head losses in turbines and waterways can be calculated simultaneously. The Búrfell power station is used an example when presenting the model used and the method in calculations.
Original language | English |
---|---|
Publisher | Landsvirkjun |
Number of pages | 8 |
Publication status | Published - 1 May 1986 |
Bibliographical note
Skýrsla unnin fyrir Landsvirkjun, (8 pp/bls).Other keywords
- Hydraulics
- Water discharge
- Electric power